Measurement of Liquid Volume in Stomach Using 6-Elctorde FIM for Saline Water Intake at Periodic Intervals

Authors

  • Samiron K. Saha

  • Pretam K. Das

incorporated measurement for reproducibility

Abstract

Focused Impedance Measurement (FIM) is a relatively new technique developed in the Biomedical Physics Laboratory of Dhaka University which allows improved localization of a zone without much increase in complexity of the measuring instrumentation when the electrodes are applied on the skin surface with the organs inside contributing the measurement of impedance since the body is a volume conductor. The present work is basically a preliminary study which aims at measuring the absolute volume of food or drinks of known conductivity inside a human stomach. The circuitry of a FIM system was used to study the impedance change in the stomach region of two subjects for the intake of saline (water with a little salt) with a particular conductivity on several days, each day with a different volume of the saline. It was ensured that they had the same history of food intake in the previous day and all physical conditions remain the same during the measurement for reproducibility. The impedance changes for different volumes of the saline in the one subject agreed well, and it appears that provided the correction factors mentioned above are incorporated, FIM may be used to measure the volume of food or saline in the stomach of a person.

Downloads

How to Cite

Measurement of Liquid Volume in Stomach Using 6-Elctorde FIM for Saline Water Intake at Periodic Intervals. (2013). Global Journal of Science Frontier Research, 13(49), 39-43. https://journalofscience.org/index.php/GJSFR/article/view/

Author Biographies

Samiron K. Saha

Atomic, Molecular and Optical Physics, Biophysics, Bioscience, Medical Physics

Pretam K. Das

Dr. Pretam K. Das is an accomplished physicist and academic currently serving as an Associate Professor in the Department of Physics at Pabna University of Science and Technology (PUST), Bangladesh, a position he has held since 2019. Concurrently, he is a Postdoctoral Research Scholar at Jan Kochanowski University in Kielce, Poland, since 2026. His career includes a Postdoctoral Research Fellowship at the Joint Institute for Nuclear Research (JINR) in Dubna, Russia (2023–2024), a Senior Instructor role at Eastern Mediterranean University in Cyprus (2022), and earlier faculty appointments at PUST as Assistant Professor (2013–2019) and Lecturer (2012–2013), as well as a Lecturer at Chittagong University of Engineering & Technology (2011–2012). Dr. Das earned his M.Sc. (2010) and B.Sc. (Hons) (2009) in Physics from the University of Rajshahi, Bangladesh, and has collaborated as a researcher at Indiana University. His research spans nuclear physics, neutron capture reactions, laser-plasma interactions, and electron-atom interactions, supported by grants from the Japanese Government (MEXT), JINR, IIT Kharagpur, and PUST. He is an active member of the American Physical Society. With 33 publications, 242 citations, an h-index of 7, and an i10-index of 6, Dr. Das continues to contribute significantly to experimental and theoretical physics.

References

K. Rabbani, M. Sarker, M. Akond, T. Akter (1999) Focused Impedance Measurement (FIM): A New Technique with Improved Zone Localization. 873(1), 408-420. https://doi.org/10.1111/j.1749-6632.1999.tb09490.x

K. Rabbani, M. Sarker, M. Akond, T. Akter (1998) Focused Impedance Measurement (FIM): A New Technique with Improved Zone Localization. 31-34.

K. Rabbani (2010) Focused Impedance Measurement (FIM) and Pigeon Hole Imaging for localized measurements - a review. 224, 012003.

K. Rabbani, M. Sarker, M. Akond, T. Akter (1998) Focused Impedance measurement using six electrodes, a new technique for localizing objects under the surface in a volume conductor.

Kamila Afroj Quadir, Fuad Nasir, Mahmudur Rahman, K. Rabbani (2004) A New Approach to Electrical Impedance Imaging Technique.

Measurement of Liquid Volume in Stomach using 6-Elctorde FIM for Saline Water Intake at Periodic Intervals

Published

2013-10-14

How to Cite

Measurement of Liquid Volume in Stomach Using 6-Elctorde FIM for Saline Water Intake at Periodic Intervals. (2013). Global Journal of Science Frontier Research, 13(49), 39-43. https://journalofscience.org/index.php/GJSFR/article/view/