Quick Simultaneous Determination of NMP and DMAC in Synthetic Fibers by Py-GC-MS using a Thermal Desorption Function

Authors

  • Eun Kyung Choe

  • Moon Hwan Song

  • Young Dal Cho

NMP, DMAc, solvent residues, synthetic fibers, thermal desorption, Py-GC-MS

Abstract

The simultaneous analyses of NMP and DMAc in synthetic fibers that have been regulated recently due to their human hazard properties were studied by both a conventional GC-MS method and a thermal desorption(TD)-GC-MS method that uses Py-GC-MS instrument using the thermal desorption function. Method validation characteristics such as linearity, precision of peak area and retention time, limit of quantification on their determination using a new TD-GC-MS method were found to be acceptable according to the well-recognized method validation guidelines and the current regulation limit. Recovery ratios of DMAc from the spiked synthetic fibers were estimated to be 95.2% to 97.1% with Soxhlet extraction using methanol as measured by GC-MS. Residual amounts of NMP and DMAc in commercial meta-aramid, polyester, and spandex fibers were measured by and GC-MS and TD-GC-MS, respectively and showed a good correlation between two methods with the ratio of 85.5% to 119%. Results of this study suggested that the TD-GC-MS analysis can provide both a good screening and a quick determination of NMP and DMAc in synthetic fibers without any solvent extraction of fiber samples that is a routine and time consuming pretreatment in the conventional GC-MS analysis.

How to Cite

Quick Simultaneous Determination of NMP and DMAC in Synthetic Fibers by Py-GC-MS using a Thermal Desorption Function. (2016). Global Journal of Science Frontier Research, 16(5), 17-23. https://journalofscience.org/index.php/GJSFR/article/view/

References

L. Yao, C. Lee, J. Kim (2010) Fiber. 11, 1032.

N-Methyl-2-Pyrrolidone, Application data sheet prepared by Lyondell Basell. http://www.lyondellbasell.com/techlit/techlit/2313.pdf

V. Gabara, J. Hartzler, K. Lee, D. Rodini, H. Yang (2006) Handbook of Fiber Chemistry.

M. Headinger, E. Rudisill, D. Luckey (2010) 2010, 7771637 B2.

T. Tai, J. Masson, D. Rodini, R. Leonard (1997) EP Patent, 1997, 0808922 A1. 19.

R. Robello, F. Calenti, D. JahiČ, M. MikuŽ (2013) WO Patent, 2013, 2013032408 A1.

N. N,N-Dimethylaceamide, areas of application prepared by BASF, /corporate/en/brand/N_N_DIMETHYLACETAMIDE. http://www.basf.com/group/corporate/en/brand/N_N_DIMETHYLACETAMIDE

(2011) Identification of 1-Methyl-2-pyrrolidone as a substance of very high concern because of its CMR properties, SVHC support document prepared by European Chemicals Agency (ECHA), 2011. http://echa.europa.eu/documents/10162/88a09054-cdf6-4629-9745-f0b5562d224a

Identification N (2011) Identification of N,N-Dimethylacetamide as a substance of very high concern because of its CMR properties, SVHC support document prepared by ECHA, 2011, /10162/88a09054-cdf6-4629-9745-f0b5562d224a. 4629-9745. http://echa.europa.eu/documents/10162/88a09054-cdf6-4629-9745-f0b5562d224a

Compilation ECHA Candidate list of substances of very high concern for authorization, Compilation prepared by ECHA. http://echa.europa.eu/candidate-list-table

WAC 173-334-130, The reporting list of chemicals of high concern to children (CHCC list). 173-334. http://www.ecy.wa.gov/programs/swfa/cspa/index.html

(2012) General and special conditions for the authorization to use the Oeko-Tex® Standard 100 mark.

(2014) Testing procedures for authorization to use the Oeko-Tex® Standard 100 mark.

(2005) Validation of analytical procedures: text and methodology Q2(R1). http://www.ich.org/fileadmin/Public_Web_Site/ICH_Products/Guidelines/Quality/Q2_R1/Step4/Q2_R1__Guideline.pdf

(2009) Guidance for the Validation of Analytical Methodology and Calibration of Equipment used for Testing of Illicit Drugs in Seized Materials and Biological Specimens.

Y. Juillet, C. Dubois, F. Bintein, J. Dissard, A. Bossée (2014) Anal Bioanal Chem., 2014. 406, 5137.

K. Han, J. Zhang, P. Wargocki, H. Knudsen, B. Guo (2010) Indoor Air. 2010. 20, 341.

by Equipment, Materials International Revision to SEMI MF1982-1110, Test methods for analyzing organic contaminants on silicon wafer surfaces by thermal desorption gas chromatography, by Semiconductor Equipment and Materials International, cb7c9/87288ca3540e320488257bff0017ab6f/$FILE/ 5389. http://downloads.semi.org/web/wstdsbal.nsf/2b382bdda3c2abca88256fcd007cb7c9/87288ca3540e320488257bff0017ab6f/$FILE/5389.pdf

M. Song, Y. Cho, E. Choe

I. Taverniers, M. De Loose, E. Van Bockstaele (2004) Trends Anal. 23, 535.

Ludwig Huber (2007) Validation and Qualification in Analytical Laboratories.

easy A fast A fast, easy and green thermal desorption-GC/MS method for the analysis of phthalate esters in PVC. http://www.frontier-lab.com/techinfo/phthalate/pdf/Phthalate_technical_brief.pdf

T. Yuzawa, C. Watanabe, R. Freeman, S. Tsuge (2009) 25, 1057.

Astm D (2013) Standard Test Method for the Determination of Low Level, Regulated Phthalates in Poly (Vinyl Chloride) Plastics by Thermal Desorption- Gas Chromatography/Mass Chromatography. https://doi.org/10.1520/d7823-13

Quick Simultaneous Determination of NMP and DMAC in Synthetic Fibers by Py-GC-MS using a Thermal Desorption Function

Published

2016-02-22

How to Cite

Quick Simultaneous Determination of NMP and DMAC in Synthetic Fibers by Py-GC-MS using a Thermal Desorption Function. (2016). Global Journal of Science Frontier Research, 16(5), 17-23. https://journalofscience.org/index.php/GJSFR/article/view/